Observation of the Ξb0

Decay chains
Ξb-→ Ξc0π-, Ξc0→ Ξ-π+, Ξ-→ Λ π-, Λ → p π- and Ξb0→ Ξc+π-, Ξc+→ Ξ-π+π+, Ξ-→ Λ π-, Λ → p π-
Figures in support of the analysis:
eps version
pπ distribution in a 44 pb-1 subset of the data. Shaded area indicates the signal region.
eps version
Λ π distribution in a 44 pb-1 subset of the data. Shaded area indicates the signal region.
eps version
Λ K; distribution in a 44 pb-1 subset of the data. Shaded area indicates the signal region. This is not used in this analysis.
eps version
Λπ distribution in a 44 pb-1 subset of the data, where SVX II hits are required on the Ξ- track and the impact with respect to the beam is less than 100 μm. Shaded area indicates the signal region. eps version
Λ K distribution in a 44 pb-1 subset of the data, where SVX II hits are required on the Ξ- track and the impact with respect to the beam is less than 100 μm. . Shaded area indicates the signal region. This is not used in this analysis.
eps version
The Ξ-π+ mass distribution. Shaded areas indicate the signal region and mass sideband regions.
eps version
The Ξ-π+π+ mass distribution. Shaded areas indicate the signal region and mass sideband regions.
eps version
Λ K; distribution in a 44 pb-1 subset of the data. Shaded area indicates the signal region. This is not used in this analysis.
eps version
The Λc+π- mass distribution. A fit to the data is superimposed.
eps version
The Λc+π- mass distribution where the impact to the beam is less than 100 μm. A fit to the data is superimposed.
eps version
The Λc+π- mass distribution for the subset with -70 μm < ct(Λc+) < 200 μm. A fit to the data is superimposed.
eps version
The Λc+π- mass distribution for the subset with -2σ < ct(Λc+) < 3c&tau(Λc+) + 2σ. A fit to the data is superimposed.
eps version
The Ξc0π- mass distribution without impact or decay Ξc0 time requirements.
eps version
The Ξc0π- mass vs. the impact.
eps version
The Ξc0π- mass distribution for the subset with |impact| < 100 μm.
eps version
The Ξc0π- mass vs. the decay time of the Ξc0.
eps version
The Ξc0π- mass distribution for the subset with -2σct < ct(Ξc0) < 3cτ + 2σct.
eps version
Ξc0 π- distribution.
eps version
Ξc0 π- distribution.
eps version
The Ξ-π+π- mass vs. the Ξ-π+ mass.
eps version
The Ξ0π+π- mass distribution for candidates consistent with Ξc0 combinations and for the mass sidebands.
eps version
The Ξc+π- mass distribution without impact or decay Ξc+ time requirements.
eps version
The Ξc+π- mass vs. the impact.
eps version
The Ξc+π- mass distribution for the subset with |impact| < 100 μm.
eps version
The Ξc+π- mass vs. the decay time of the Ξc+.
eps version
The Ξc+π- mass distribution for the subset with -2σct < ct(Ξc+) < 3cτ + 2σct.
eps version
Ξc+ π- distribution.
eps version
Ξc+ π- distribution.
eps version
The Ξ-π+π+π- mass vs. the Ξ-π+π+ mass.
eps version
The Ξ0π+π+π- mass distribution for candidates consistent with Ξc+ combinations and for the mass sidebands.
eps version
Ξc0 π- distribution. The projection of the unbinned likelihood fit is overlaid in a dashed line. eps version
Ξc+ π- distribution. The projection of the unbinned likelihood fit is overlaid in a dashed line. eps version
Ξ- π+ distribution. The projection of the unbinned likelihood fit is overlaid in a dashed line. eps version
Ξ- π+ π+ distribution. The projection of the unbinned likelihood fit is overlaid in a dashed line.