This report describes the performance of the CDF Plug Upgrade calorimeter measured at the Fermilab Meson Beam line. A 60^o section of the Electromagnetic and Hadronic calorimeters has been exposed to e^+, pi^+ and mu^+ beams. We determine an every resolutions of sigma(E)/E = 15.5%/sqrt E for the Electromagnetic and sigma(E)/E = 78%/sqrt E \oplus 5.3% for the Hadronic Calorimeters (E measured in GeV). The linearity of transverse response is 1.6% for e^+ and 2.3% for pi^+. The Shower Maximum Detector, instrumenting the EM calorimeter, provides a position resolution of 1 mm for e^+ energies above 50 GeV. The detector calibration system, based on a set of movable Cs^137 sources, is able to track the energy scale at the level of \sim 1 - 2 %.